Spezifikationstabelle für ETSX-D / EPRA014-018DW

ETSX16P30DA / EPRA14DAW1 ETSX16P50DA / EPRA14DAW1 ETSX16P30DA / EPRA16DAW1 ETSX16P50DA / EPRA16DAW1 ETSX16P30DA / EPRA18DAW1 ETSX16P50DA / EPRA18DAW1
Innengerät ETSX16P30DA ETSX16P50DA ETSX16P30DA ETSX16P50DA ETSX16P30DA ETSX16P50DA
Außengerät EPRA14DAW1 EPRA14DAW1 EPRA16DAW1 EPRA16DAW1 EPRA18DAW1 EPRA18DAW1
Heizleistung Nom. kW 5.69 (1) 5.69 (1) 9.00 (1) 9.00 (1) 9.00 (1) 9.00 (1)
Leistungsaufnahme Heizen Nom. kW 1.22 (1) 1.22 (1) 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1)
  Warmwasser von 10 °C bis 50 °C Nom. kWh 3.50 5.78 3.50 5.78 3.50 5.78
Heat up time from 10°C to 50°C hr 1h25min at 7°C ambient temperature 2h18min at 7°C ambient temperature 1h25min at 7°C ambient temperature 2h18min at 7°C ambient temperature 1h25min at 7°C ambient temperature 2h18min at 7°C ambient temperature
COP 4.66 (1) 4.66 (1) 5.00 (1) 5.00 (1) 5.00 (1) 5.00 (1)
Pumpe Type   Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT
Wasserseitiger Wärmetauscher Wasserdurchfluss Heizen Nom. l/min 16.3 (1) 16.3 (1) 25.8 (1) 25.8 (1) 25.8 (1) 25.8 (1)
Allgemein Lieferanten-/Herstellerdetails Name und Adresse   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Name oder Marke   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Produktbeschreibung Luft-zu-Wasser-Wärmepumpe   Ja Ja Ja Ja Ja Ja
    Sole-zu-Wasser-Wärmepumpe   Nein Nein Nein Nein Nein Nein
    Wärmepumpenkombination Heizer   Ja Ja Ja Ja Ja Ja
    Niedertemperatur-Wärmepumpe   Nein Nein Nein Nein Nein Nein
    Integrierter Zusatzheizer   Nein Nein Nein Nein Nein Nein
    Wasser-zu-Wasser-Wärmepumpe   Nein Nein Nein Nein Nein Nein
  LW(A) Schallleistungspegel (entsprechend EN14825) Innen dB(A) 45.6 45.6 45.6 45.6 45.6 45.6
LW(A) Schallleistungspegel (gemäß EN14825) Außen dB(A) 54.0 54.0 54.0 54.0 54.0 54.0
Schallbedingungen Ökodesign-Richtlinie und Energieeffizienzklasse Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825
Raumheizen allgemein Luft-zu-Wasser-Gerät Nenn-Luftstrom (außen) m³/h 3,918 3,918 3,918 3,918 3,960 3,960
  Sonstiges Leistungsregelung   Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (Modus AUS) kW 0.031 0.031 0.031 0.031 0.031 0.031
    Psb (Standby-Modus) kW 0.042 0.042 0.042 0.042 0.042 0.042
    Pto (Thermostat AUS) kW 0.033 0.033 0.033 0.033 0.033 0.033
  Integrierter Zusatzheizer Art der Energieaufnahme   Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch
Warmwasserbereitung Allgemein Deklariertes Lastprofil   L XL L XL L XL
    Funktion für feste Wasseraufheizung während Spitzenstunden   Ja Ja Ja Ja Ja Ja
  Durchschnittliches Klima AEC (Jährlicher Stromverbrauch) kWh 1,017 1,506 1,017 1,506 1,017 1,506
    Domestic hot water heating-=-Average climate-=-COPdhw   2.38 2.67 2.38 2.67 2.38 2.67
    Domestic hot water heating-=-Average climate-=-Mixed water at 40°C-=-l l 149.0 237.2 149.0 237.2 149.0 237.2
    Ƞwh (Wasserheizeffizienz) % 101 111 101 111 101 111
    Qelec (Täglicher Stromverbrauch) kWh 4.904 7.140 4.904 7.140 4.904 7.140
    Domestic hot water heating-=-Average climate-=-Reference hot water temperature-=-°C °C 47.0 47.0 47.0 47.0 47.0 47.0
    Domestic hot water heating-=-Average climate-=-Stand-by power input-=-W W 49.0 51.0 49.0 51.0 49.0 51.0
    Energieeffizienzklasse Wasserheizung   A A A A A A
  Kaltes Klima AEC (Jährlicher Stromverbrauch) kWh 1,136 1,669 1,136 1,669 1,136 1,669
    Domestic hot water heating-=-Cold climate-=-COPdhw   2.13 2.41 2.13 2.41 2.13 2.41
    Domestic hot water heating-=-Cold climate-=-Mixed water at 40°C-=-l l 149.0 237.2 149.0 237.2 149.0 237.2
    Ƞwh (Wasserheizeffizienz) % 90 100 90 100 90 100
    Qelec (Täglicher Stromverbrauch) kWh 5.476 7.902 5.476 7.902 5.476 7.902
    Domestic hot water heating-=-Cold climate-=-Reference hot water temperature-=-°C °C 47.0 47.0 47.0 47.0 47.0 47.0
  Warmes Klima AEC (Jährlicher Stromverbrauch) kWh 891 1,430 891 1,430 891 1,430
    Domestic hot water heating-=-Warm climate-=-COPdhw   2.69 2.81 2.69 2.81 2.69 2.81
    Domestic hot water heating-=-Warm climate-=-Mixed water at 40°C-=-l l 149.0 237.2 149.0 237.2 149.0 237.2
    Ƞwh (Wasserheizeffizienz) % 115 117 115 117 115 117
    Qelec (Täglicher Stromverbrauch) kWh 4.330 6.794 4.330 6.794 4.330 6.794
    Domestic hot water heating-=-Warm climate-=-Reference hot water temperature-=-°C °C 47.0 47.0 47.0 47.0 47.0 47.0
Raumheizen Wasserauslass 55 °C für durchschnittliches Klima Allgemein Jährlicher Energieverbrauch kWh 7,122 7,122 7,122 7,122 7,122 7,122
      Saisonale Effizienz Raumheizen % 142 142 142 142 142 142
      Prated bei -10 °C kW 13 13 13 13 13 13
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj 26 26 26 26 26 26
      SCOP   3.63 3.63 3.63 3.63 3.63 3.63
      Saisonale Effizienzklasse Raumheizen   A++ A++ A++ A++ A++ A++
    Bedingung A (-7 °C TK/-8 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.43 2.43 2.43 2.43 2.43 2.43
      Pdh kW 11.1 11.1 11.1 11.1 11.1 11.1
      PERd % 97.2 97.2 97.2 97.2 97.2 97.2
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.52 3.52 3.52 3.52 3.52 3.52
      Pdh kW 6.7 6.7 6.7 6.7 6.7 6.7
      PERd % 140.8 140.8 140.8 140.8 140.8 140.8
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.54 4.54 4.54 4.54 4.54 4.54
      Pdh kW 6.5 6.5 6.5 6.5 6.5 6.5
      PERd % 181.6 181.6 181.6 181.6 181.6 181.6
    Bedingung D (12 °C TK/11 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.97 5.97 5.97 5.97 5.97 5.97
      Pdh kW 5.2 5.2 5.2 5.2 5.2 5.2
      PERd % 238.8 238.8 238.8 238.8 238.8 238.8
    Tol (Temperatur-Betriebsgrenze) COPd   2.12 2.12 2.12 2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8 84.8 84.8 84.8
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55
    Nenn-Heizleistung Zusatzheizung Psup (bei Tdesign -10 °C) kW 0.0 0.0 0.0 0.0 0.0 0.0
    Tbiv (bivalente Temperatur) COPd   2.12 2.12 2.12 2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8 84.8 84.8 84.8
      Tbiv °C -10 -10 -10 -10 -10 -10
  Wasserauslass kaltes Klima 55 °C Allgemein Jährlicher Energieverbrauch kWh 9,589 9,589 9,589 9,589 9,589 9,589
      Saisonale Effizienz Raumheizen % 126 126 126 126 126 126
      Prated bei -22°C kW 13 13 13 13 13 13
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj 35 35 35 35 35 35
    Bedingung A (-7 °C TK/-8 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.74 2.74 2.74 2.74 2.74 2.74
      Pdh kW 7.5 7.5 7.5 7.5 7.5 7.5
      PERd % 109.6 109.6 109.6 109.6 109.6 109.6
    Bedingung B (2 °C TK/1 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.67 3.67 3.67 3.67 3.67 3.67
      Pdh kW 5.8 5.8 5.8 5.8 5.8 5.8
      PERd % 146.8 146.8 146.8 146.8 146.8 146.8
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.69 4.69 4.69 4.69 4.69 4.69
      Pdh kW 5.6 5.6 5.6 5.6 5.6 5.6
      PERd % 187.6 187.6 187.6 187.6 187.6 187.6
    Bedingung D (12 °C TK/11 °C FK) COPd   6.12 6.12 6.12 6.12 6.12 6.12
      Pdh kW 6.2 6.2 6.2 6.2 6.2 6.2
      PERd % 244.8 244.8 244.8 244.8 244.8 244.8
    Tol (Temperatur-Betriebsgrenze) COPd   1.65 1.65 1.65 1.65 1.65 1.65
      Pdh kW 10.6 10.6 10.6 10.6 10.6 10.6
      PERd % 66.0 66.0 66.0 66.0 66.0 66.0
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 55 55 55 55 55 55
    Bedingung G (-15 °C TK/–) COPd   2.17 2.17 2.17 2.17 2.17 2.17
      Pdh kW 10.3 10.3 10.3 10.3 10.3 10.3
      PERd % 86.8 86.8 86.8 86.8 86.8 86.8
    Tbiv (bivalente Temperatur) COPd   1.90 1.90 1.90 1.90 1.90 1.90
      Pdh kW 11.0 11.0 11.0 11.0 11.0 11.0
      PERd % 76.0 76.0 76.0 76.0 76.0 76.0
      Tbiv °C -18 -18 -18 -18 -18 -18
    Nenn-Heizleistung Zusatzheizung Psup (bei Tdesign -22°C) kW 1.9 1.9 1.9 1.9 1.9 1.9
  Warmes Klima Wasserauslass 55 °C Allgemein Jährlicher Energieverbrauch kWh 3,926 3,926 3,926 3,926 3,926 3,926
      Ƞs (Saisonale Effizienz Raumheizen) % 167 167 167 167 167 167
      Prated bei 2°C kW 13 13 13 13 13 13
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj 14 14 14 14 14 14
    Bedingung B (2 °C TK/1 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 11.4 11.4 11.4 11.4 11.4 11.4
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.65 3.65 3.65 3.65 3.65 3.65
      Pdh kW 8.2 8.2 8.2 8.2 8.2 8.2
      PERd % 146.0 146.0 146.0 146.0 146.0 146.0
    Bedingung D (12 °C TK/11 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.37 5.37 5.37 5.37 5.37 5.37
      Pdh kW 6.1 6.1 6.1 6.1 6.1 6.1
      PERd % 214.8 214.8 214.8 214.8 214.8 214.8
    Tbiv (bivalente Temperatur) COPd   3.18 3.18 3.18 3.18 3.18 3.18
      Pdh kW 11.0 11.0 11.0 11.0 11.0 11.0
      PERd % 127.2 127.2 127.2 127.2 127.2 127.2
      Tbiv °C 4 4 4 4 4 4
  Space heating-=-Water outlet 45°C Space heating-=-Water outlet 45°C-=-H Condition (-2°C / - ) Space heating-=-Water outlet 45°C-=-H Condition (-2°C / - )-=-Max.-=-kW kW 11.1 11.1 11.8 11.8 11.8 11.8
  Wasserauslass 35°C für durchschnittliches Klima Allgemein SCOP   4.57 4.57 4.57 4.57 4.57 4.57
      Jährlicher Energieverbrauch kWh 5,651 5,651 5,651 5,651 5,651 5,651
      Ƞs (Saisonale Effizienz Raumheizen) % 180 180 180 180 180 180
      Prated bei -10 °C kW 13 13 13 13 13 13
      Jährlicher Energieverbrauch (GCV) Gj 20 20 20 20 20 20
      Saisonale Effizienzklasse Raumheizen   A+++ A+++ A+++ A+++ A+++ A+++
    Bedingung A (-7 °C TK/-8 °C FK) COPd   3.07 3.07 3.07 3.07 3.07 3.07
      Pdh kW 10.6 10.6 10.6 10.6 10.6 10.6
      PERd % 122.8 122.8 122.8 122.8 122.8 122.8
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.49 4.49 4.49 4.49 4.49 4.49
      Pdh kW 6.5 6.5 6.5 6.5 6.5 6.5
      PERd % 179.6 179.6 179.6 179.6 179.6 179.6
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.75 5.75 5.75 5.75 5.75 5.75
      Pdh kW 6.1 6.1 6.1 6.1 6.1 6.1
      PERd % 230.0 230.0 230.0 230.0 230.0 230.0
    Bedingung D (12 °C TK/11 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.97 6.97 6.97 6.97 6.97 6.97
      Pdh kW 5.5 5.5 5.5 5.5 5.5 5.5
      PERd % 278.8 278.8 278.8 278.8 278.8 278.8
    Tol (Temperaturbetriebsgrenze) COPd   2.84 2.84 2.84 2.84 2.84 2.84
      Pdh kW 11.8 11.8 11.8 11.8 11.8 11.8
      PERd % 113.6 113.6 113.6 113.6 113.6 113.6
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35
    Tbiv (bivalente Temperatur) COPd   3.13 3.13 3.13 3.13 3.13 3.13
      Pdh kW 10.6 10.6 10.6 10.6 10.6 10.6
      PERd % 125.2 125.2 125.2 125.2 125.2 125.2
      Tbiv °C -7 -7 -7 -7 -7 -7
    Nennleistung Wärmeabgabe Zusatzheizer Psup (bei Tdesign -10 °C) kW 0.7 0.7 0.7 0.7 0.7 0.7
  Wasserauslass kaltes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh 7,356 7,356 7,356 7,356 7,356 7,356
      Ƞs (Saisonale Effizienz Raumheizen) % 165 165 165 165 165 165
      Prated bei -22°C kW 13 13 13 13 13 13
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj 26 26 26 26 26 26
    Bedingung A (-7 °C TK/-8 °C FK) COPd   3.50 3.50 3.50 3.50 3.50 3.50
      Pdh kW 8.0 8.0 8.0 8.0 8.0 8.0
      PERd % 140.0 140.0 140.0 140.0 140.0 140.0
    Bedingung B (2 °C TK/1 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.07 5.07 5.07 5.07 5.07 5.07
      Pdh kW 4.9 4.9 4.9 4.9 4.9 4.9
      PERd % 202.8 202.8 202.8 202.8 202.8 202.8
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.10 6.10
      Pdh kW 5.3 5.3 5.3 5.3 5.3 5.3
      PERd % 244.0 244.0 244.0 244.0 244.0 244.0
    Bedingung D (12 °C TK/11 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.03 7.03 7.03 7.03 7.03 7.03
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 281.2 281.2 281.2 281.2 281.2 281.2
    Tol (Temperatur-Betriebsgrenze) COPd   2.16 2.16 2.16 2.16 2.16 2.16
      Pdh kW 10.1 10.1 10.1 10.1 10.1 10.1
      PERd % 86.4 86.4 86.4 86.4 86.4 86.4
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 35 35 35 35 35 35
    Bedingung G (-15 °C TK/–) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
    Tbiv (bivalente Temperatur) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
      Tbiv °C -15 -15 -15 -15 -15 -15
    Nennleistung Wärmeabgabe Zusatzheizer Psup (bei Tdesign -22°C) kW 2.4 2.4 2.4 2.4 2.4 2.4
  Wasserauslass warmes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh 2,855 2,855 2,855 2,855 2,855 2,855
      Ƞs (Saisonale Effizienz Raumheizen) % 231 231 231 231 231 231
      Prated bei 2°C kW 13 13 13 13 13 13
      Jährlicher Energieverbrauch (GCV) Gj 10 10 10 10 10 10
    Bedingung B (2 °C TK/1 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.51 3.51 3.51 3.51 3.51 3.51
      Pdh kW 10.0 10.0 10.0 10.0 10.0 10.0
      PERd % 140.4 140.4 140.4 140.4 140.4 140.4
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.67 5.67 5.67 5.67 5.67 5.67
      Pdh kW 8.3 8.3 8.3 8.3 8.3 8.3
      PERd % 226.8 226.8 226.8 226.8 226.8 226.8
    Tbiv (bivalente Temperatur) COPd   4.96 4.96 4.96 4.96 4.96 4.96
      Pdh kW 9.8 9.8 9.8 9.8 9.8 9.8
      PERd % 198.4 198.4 198.4 198.4 198.4 198.4
      Tbiv °C 5 5 5 5 5 5
    Bedingung D (12 °C TK/11 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.04 7.04 7.04 7.04 7.04 7.04
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 281.6 281.6 281.6 281.6 281.6 281.6
Notes_Description 1 1 1 1 1 1